Catching Fabricated Detail in Generated Clinical Notes

In short This article categorises the failure modes — invented negatives, carried-over history, wrong tooth notation — and gives a targeted check for each rather than a full re-read.

Route ahead 6 sections
  1. Why a full re-read fails
  2. Failure mode 1: invented negatives 1 min
  3. Failure mode 2: carried-over history 2 min
  4. Failure mode 3: wrong tooth notation 4 min
  5. A 45-second review routine 5 min
  6. Measuring whether it is working 6 min

An AI scribe that writes “no sensitivity, no swelling, patient reports no allergies” has just made three clinical statements. Did the patient say any of them? That is the question every principal needs to be able to answer, and “read the whole note again” is not a workable answer at 28 patients a day.

AI clinical notes errors are not random typos. They fall into a small number of repeatable categories, and each category has a cheap, specific check. If you know the category, you can check in seconds. This post sets out the three that matter most in UK general practice, with a targeted check for each.

Why a full re-read fails

Ambient scribes and dictation-to-note tools (Heidi Health, Tandem Health, Nabla, and the note-drafting features inside practice management systems such as Software of Excellence’s Exact, or Carestream’s and Dentally’s integrations) produce fluent text. Fluent text is the problem. A fabricated sentence reads exactly like a true one, so a tired clinician skims, sees the right headings, and signs.

Consider a typical 10-minute examination appointment. The note runs to around 250 words. A genuine line-by-line proofread takes perhaps 90 seconds. Over 24 patients that is 36 minutes a day per clinician, and in practice it won’t happen after the first fortnight. A 20-second check aimed at the places where errors cluster will actually be done.

The GDC’s standards on record keeping (Standards for the Dental Team, section 4.1) put the responsibility on you, not the software: records must be complete, accurate and contemporaneous. A scribe is a drafting aid. Your signature is the clinical statement.

Failure mode 1: invented negatives

This is the most dangerous one, and the most common. The model has seen thousands of examination notes, and most of them contain a reassuring negative. So it supplies one.

What it looks like

What was said in the surgeryWhat the note says
“Any pain at all with that tooth?” Patient: “A bit on cold.”“Sensitivity to cold. No spontaneous pain. No pain on biting.”
(Soft tissues examined, nothing said aloud)“No suspicious lesions. Lymph nodes NAD. Oral cancer screen: negative.”
(Nobody asked about medical history)“No change to medical history. No known allergies.”

The second row is the one that hurts you. If the clinician examined the soft tissues but narrated nothing, the scribe has nothing to transcribe, so it fills the gap with the template default. A negative oral cancer screen that was never spoken is a medicolegal problem if the patient later presents with a lesion that was actually there.

The targeted check: search for negatives, then ask “did I say that?”

Scan only for the words no, nil, NAD, denies, negative, normal, unremarkable, nothing. Every hit is a claim of absence. For each, ask whether you actually looked or asked. Delete any you did not.

This takes about 15 seconds. On a 250-word note you will usually find four to eight negatives, and you only need to verify those.

The structural fix: say your negatives aloud. “No lymphadenopathy, soft tissues clear, no ulcers over three weeks.” It feels odd for a week and then becomes habit. It also gives the tool real speech to transcribe instead of a gap to fill. And in procurement, ask the vendor directly: does the tool ever add findings that were not in the audio, and can it be configured to leave a section blank? Prefer products that flag unsupported lines or link each sentence to the transcript.

Failure mode 2: carried-over history

Tools that pull context from the previous record, or that reuse a template, can drag old information into today’s note as though it were new.

Worked example

Mrs K, 54, attended in March for an upper right molar with a deep restoration. The note recorded: “Patient reports on warfarin, INR 2.4 last week. Advised to continue.” She attended again in October for a routine recall. The October draft read:

PMH: On warfarin, INR 2.4. No changes.
Extraction of LR6 discussed. Haemostasis measures not required.

Two errors. Her warfarin had been stopped in July after her cardiologist changed her to a different anticoagulant, and the INR value was seven months old. Nobody had discussed an extraction. The “LR6” came from a treatment plan item still open on her record. The note merged three different dates into one present-tense paragraph.

The targeted check: look at tense and dates

  • Find every number with a unit or a date: INR, HbA1c, blood pressure, doses, “last week”. Ask whether it was measured or stated today.
  • Find every medication. Ask whether the patient confirmed it at this visit.
  • Find every procedure mentioned. Was it discussed, or merely planned previously?

Better still, make the medical history update a spoken, separate step at the start of every course of treatment, and at least every 12 months for recall patients. “Has anything changed with your health or tablets since I last saw you?” The answer is then in the audio, and anything in the note that is not in the audio is suspect.

For practices on NHS contracts, remember the history matters for more than safety. Old information carried forward can also muddy your claim record. A treatment recorded as discussed but never delivered is a problem in a UDA audit.

Procurement question: does the tool read from the existing patient record, and if so, how does it mark text drawn from history versus text from today’s conversation? If it cannot show the difference, the burden of separating them falls on you.

Failure mode 3: wrong tooth notation

Dentistry has three notation systems in everyday use: FDI two-digit (the standard in the UK), Palmer (the quadrant grid, often typed as UR6, LL8), and Universal (1 to 32, American). Speech recognition and language models both stumble here.

Typical errors

SpokenWrong outputWhy
“Lower left six”LL6 recorded as 36 in one line, 46 in the nextFDI quadrant swapped
“Upper right eight, distal”18D, then “tooth 18” meaning Universal tooth 18 (a lower left molar)System mixing
“Four six, mesial occlusal”“46 MO” or “4, 6 MO” or “forty-six”Number parsing
“Upper E”UE as a primary tooth, written as 55Primary teeth (51-85) are rarely handled well

The ones that cause real harm are laterality flips (left for right) and primary tooth confusion in children. A note that says 16 instead of 26 on an extraction record is the sort of entry that turns up in a complaint file, and it can also lead to the wrong site being treated if someone reads the note rather than the radiograph.

The targeted check: cross-read teeth against the chart, once

Do not reread the prose. Pull out every tooth number in the note and compare the list with three things: the tooth you actually treated, the radiograph, and the odontogram. Count them. If you mentioned three teeth aloud and the note contains five, you have two to investigate.

Then check one thing separately: consistency. Does the note use one system throughout? Mixed notation in a single entry is a strong sign of a transcription fault.

A practical rule for the surgery: speak teeth in full and in one system. “Tooth two-six, mesio-occlusal composite.” Agree it as a practice policy, put it in the induction pack, and set the tool’s output notation to FDI if it allows.

A 45-second review routine

Here is how the three checks combine on a real note. Do these in order, on screen, before signing.

  1. Negatives (15 seconds). Hunt for no, nil, NAD, normal, denies. Verify or delete.
  2. Dates and drugs (15 seconds). Check every number, drug and procedure against today’s conversation.
  3. Teeth (15 seconds). List the tooth numbers. Do they match what you treated and the chart?

Run it on this deliberately flawed draft:

Pt attended for examination. PMH unchanged, on atorvastatin and warfarin.
No sensitivity, no swelling, no mobility. Soft tissues NAD. BPE 1/1/2 / 1/1/1.
Bitewings taken: caries LR6 mesial. Restoration of 36 MO planned.

Check one flags five negatives, of which the clinician only voiced “no swelling”: strike “no sensitivity”, “no mobility” and the soft tissue claim unless examined. Check two flags warfarin, which was not mentioned today. Check three finds LR6 and 36 in the same note, which are the same tooth in two systems: acceptable only if intentional, and a prompt to confirm the caries is on the lower left, not the lower right (46).

Three catches in under a minute, and none of them needed a full reread.

Measuring whether it is working

Do not trust your impression. Audit it. Once a month, pull 20 notes per clinician at random and compare each against the audio or the clinician’s recollection while it is fresh. Log each error by category: invented negative, carried history, notation, other. After two months you will know which error your tool favours, and that tells you which check to emphasise in training.

A reasonable internal target is under one fabricated clinical statement per 20 notes. If you are seeing one in five, it is a configuration or vendor problem, not a training problem, and you should escalate it in writing. Keep the audit log too: it is useful evidence for your DPIA and for your CQC or HIW inspection, where you may be asked how you assure the accuracy of AI-assisted records.

For the wider picture on templates, record standards and how scribes fit your charting workflow, see our pillar on Clinical Notes and Charting.

One final instruction for your team, and it is deliberately blunt: if a line in the note is not something you said, saw, or measured today, it does not stay in the note.