Training Associates on AI Without Eroding Their Own Reading Skills
In short This article argues for read-first-then-reveal as the house workflow, because automation bias builds fastest in the least experienced readers.
Route ahead 8 sections
A new associate joins your practice in September. Eighteen months out of foundation training, keen, a bit nervous. On day one you show them the radiograph AI: Dentalmonitor, Pearl’s Second Opinion, Overjet, Diagnocat, take your pick. Every bitewing opens with coloured outlines already drawn on it. Caries here, bone loss there, a periapical radiolucency flagged on the lower six.
It feels like a gift. It is also the quickest way to build a clinician who cannot read a bitewing unaided.
This post makes one argument: the house workflow should be read first, then reveal. The associate commits to their own findings before the software shows its overlay. Always. This matters most for the least experienced readers, and it is cheap to do. The rest is detail on why and how.
Why juniors are the exposed ones
Automation bias is the tendency to accept a machine’s suggestion over your own judgement, and to stop looking for what the machine did not flag. It is well documented in radiology generally. The pattern that keeps showing up in reader studies is that less experienced readers are swayed most, because they have the least internal reference to argue with.
Think about what a senior colleague does when the AI flags a distal lesion on the 46 that they do not see. They squint, change the contrast, compare with the previous set, and perhaps decide the software is wrong. That argument only happens if they have a trained eye to argue with. A second-year associate has seen perhaps a few thousand bitewings. A principal with twenty years behind them has seen a hundred thousand or more. The first has a pattern library under construction. If the AI paints the answer on the film before the library is built, the library never gets built properly.
There is a second problem, quieter. Missed findings. If the overlay shows four lesions, the reader tends to confirm those four and stop. Anything the model did not flag (a subtle crestal bone change, a root fracture line, an unerupted supernumerary) falls out of attention. The AI’s sensitivity ceiling becomes the associate’s ceiling.
What deskilling looks like in a real practice
Here is a worked example, with invented but plausible numbers. A five-surgery mixed NHS/private practice in the Midlands rolls out AI overlay on all bitewings. Two associates, one with 3 years’ experience, one with 11 months.
They run a simple audit before rollout and again at six months: 40 anonymised bitewing series, each with a consensus reference read from two senior colleagues. Each associate reads unaided, no AI.
| Baseline sensitivity for proximal caries | Six months, AI-on-open, unaided re-test | |
|---|---|---|
| Associate A (3 years) | 71% | 68% |
| Associate B (11 months) | 58% | 49% |
Associate A drifts by three points. Noise, mostly. Associate B loses nine, and was lower to start with. Nobody did anything wrong. B simply spent six months confirming other people’s (well, a machine’s) answers rather than making their own. The numbers are illustrative, but the shape is what the literature and common sense both predict: the junior falls furthest.
Now the same practice, same associates, but read-first-then-reveal from day one. Illustrative result at six months: A at 73%, B at 63%. Both up, because every disagreement with the AI became a small teaching moment.
The workflow, concretely
Keep it boring and make it habitual. Here is the house rule:
- Open the image with overlay off. Most platforms let you set this as the default. Pearl and Overjet both let an administrator control how findings display; if your vendor cannot do it, that is a procurement question, not a minor gripe.
- Read and record. The associate notes findings in the clinical record or on a short checklist before revealing. Even “no pathology seen, caries on mesial 36 only” is enough.
- Reveal. Toggle the AI on.
- Reconcile. Three outcomes: agreement, AI-only finding, associate-only finding. Each AI-only finding gets a second, deliberate look. Each associate-only finding gets noted too, because the machine is not always right.
- Decide and document. The clinician decides, and the record says who decided.
That is perhaps 20 to 40 seconds extra per series. On a 10-minute check-up slot that is not nothing, but it is not a disaster either. At 25 patients a day, even a generous 30 seconds is about 12 minutes of surgery time. Set against a missed interproximal lesion that becomes a pulpitis and an emergency slot, it pays for itself.
The objection you will hear
“The point of the AI is to save time.” Partly. The saving is real in front-desk admin and in triage queues, where reading skill is not what you are protecting. On radiographs, the main value is a second opinion, and a second opinion is only independent if it comes second. Reveal-first turns a second reader into a first reader with a very persuasive voice.
Another: “Our associates are already competent.” Fine. Then the cost of read-first is tiny and the audit will show it. If they are not, you want to know before the software hides it.
Medicolegal and CQC angles
Under the GDC standards, the clinician is responsible for the diagnosis. “The software did not flag it” will not carry much weight. A documented independent read before reveal is also decent evidence of reasonable care, and it fits the IR(ME)R expectation that the practitioner justifies and evaluates every exposure. The software is an aid. Your record should say so.
For NHS contract practices, nothing here changes your commissioning obligations; it just means the clinical note reflects a human reading first.
A six-month rollout plan
Month 0. Run the baseline audit: 30 to 40 series, unaided, two senior reference readers. It takes one lunchtime plus some marking. Record each associate’s sensitivity and false-positive rate.
Months 1 to 3. Read-first-then-reveal on every case. Associates log disagreements in a shared sheet: date, tooth, who was right. Hold a 30-minute case review monthly. Use the disagreements, not the agreements.
Month 3. Spot check. Pull 10 records per associate and confirm the pre-reveal note exists.
Month 6. Repeat the unaided audit with a fresh set. If an associate’s sensitivity has dropped more than five points, pause AI-on-open entirely for that person and go back to unaided reads with senior review for four weeks.
A sample entry from the disagreement log:
Date: 14/10 Pt: [ID] Film: BW right
Tooth: 46 distal
Associate read: sound
AI: D2 lesion, confidence 0.81
Senior review: radiolucency into outer third dentine, AI correct
Learning: viewed at default contrast; re-read at inverted, visible
That last line is the point. The AI taught something because the associate had committed first.
What to ask vendors
Before you sign, ask four questions. Can overlay default to off, per user? Can the platform log whether findings were viewed before or after reveal? Is there an exportable record of AI-versus-clinician disagreements? What is the published sensitivity and false-positive rate on bitewings, and in what population? If the answers are vague, treat that as the answer.
For the wider picture on choosing and running these tools, our pillar on AI Radiograph Reading covers evaluation criteria in more detail.
Make it the house rule, not a personal choice
Do not leave this to individual discipline. Tired associates at 4:30 pm will toggle the overlay on early. Put it in the practice protocol, set the default in the software, and audit it. Associates will thank you in five years, when they can still read a film in a power cut or on a dodgy monitor in a locum practice that has no AI at all.